CV-A10 CL and CV-A70 CL
7. Configuring the Camera
7.1. Switch setting by internal SW301 and SW302
SW 301 is used for communication port select and ext. HD/VD or RS232C on pin 6 and 7 12 pin.
The switches are found inside the camera on the left hand board. (Seen from rear).
To access SW301 and SW302:
Remove camera cover.
The switches are located on left hand board.
SW301 is for communication and external HD/VD in.
No Functions
ON OFF
1 Communication port switch LVDS (CameraLink) RS232C (HIROSE 12pin)
2 HIROSE 12pin No. 6 switch External HD in RS232C (RxD In)
3 HIROSE 12pin No. 7 switch External VD in RS232C (TxD Out)
4
SW 302 is for 75Ω termination of trigger and HD/VD input.
No Functions
ON OFF
1 Trigger In Termination switch 75Ω TTL
2 Reserved - -
3 External Trigger HD in Termination 75Ω TTL
4 External Trigger VD in Termination 75Ω TTL
Bold italic is factory setting
Fig. 36. Switch 301 and 302 positions on PK8437B
- 26 -